Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Specifications may have preexisting values based on Project Specs - Density.
  • Using the check box, Moisture Specifications may or may not be required.
  • After selecting a Proctor, characteristics of the Proctor will display.  These values come from Lab.
  • NOTE:  You may also view the proctor curve image by selecting View Image.  The View Image button will not exist if there are not attachments to the proctor.  For instruction on how to attach an image to a proctor, see Soil Proctor Results
  • To see more proctor metadata, select the Show More Data button.

Sand Cone Test

  • Enter in the respective fields to complete the Sand Cone Test
    Image Removed
  • Select the name of the Sand Cone you wish to use for the test.
    • Depending on the Sand Cone selected, the Sand Cone test will default according to which calibration Method ( A or B ) was used.
    • In some cases, a Sand Cone may be calibrated via Method's A & B. In this case, the use will be allowed to select the appropriate Method to use in Field.
  • Surface Condition will default to Smooth. If the surface of the test is Rough, switch this field to Rough Surface - Alternate Test Method and MetaField will adjust accordingly.

Image Added

Entering Moisture Content Data

...