Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

FieldDescription

Test Types

  • Allows you to select the Type of Test you will be performing:
  • Test Types:
      • Bituminous Nuclear Gauge
      • Moisture Content
      • Sand Cone
      • Soil Nuclear Gauge
  • This is a required field

Technician

  • Person who is performing the Test
  • Defaults to logged in user
  • This is a required field

Date Tested

  • Date test was performed
  • You may type in a date or select from a calendar
  • Defaults to current date
  • This is a required field.

Location

  • A predetermined drop-down list of locations
  • List may be preflitered based on selections made in Project Specifications
  • You can override the prefiltered list by unchecking Filter by Project
  • Global list is controlled by your MetaField Business Administrator
  • This is a required field

Location Details

  • Allows you to enter more information about your test location
  • 500 character limit
  • This is a required field.

Elevation and Elevation Reference

  • Enter the elevation for your test and any associated reference

Get Location

  • Selecting this button will automatically populate the Longitude and Latitude fields.  
  • Longitude and Latitude fields can also be edited manually.
Latitude
  • Latitude (in degrees) where the activity is happening.
Info

Up to 8 decimal places are allowed in the latitude value.

Longitude

  • Longitude (in degrees) where the activity is happening
Info

Up to 8 decimal places are allowed in the longitude value.

Project Location ID

  • Client defined field to identify granular site locations based on business process.
  • This information displays in QC only, not on reports.

  Image RemovedImage Added

Entering a Starting Analysis Number

...