1. | Add Soil Classifications on the Density Testing > Soil Classifications page - When adding the first Soil Classification, enter different Moisture Tolerance values than those listed at the top of the page.
- When adding the next Soil Classification, alter only the Lower Moisture Tolerance value.
- Optional: View your new Soil Classifications by creating a Proctor in MetaField, Lab > Add Proctor, ensuring the values appear in the dropdown list for Soil Classification.
- When you are done with this step, Deactivate or Delete the Soil Classifications you just added.
|
2. | Add a Draft Mix Design value to Field > Concrete, then activate it in Administration. To do this:- Go to MetaField, Field > Concrete Sampling and add a new Concrete Cast Cylinder Sample (select Add Sample within the Concrete / Grout / Mortar section).
- When you get to the Supplier field, select a Supplier from available options. When the Mix Design field appears, type in a new value for Mix Design (one not available on the list of choices). This value will show in red text - meaning it will be a Draft value in Administration once the test is saved.
- Continue to enter values for all required fields until you can save your Concrete Sample.
- After saving, return to Administration, General > Suppliers / Mix Designs.
- Change the filter of the Mix Designs list to Draft and locate the value you entered in Field.
- Activate the value by changing its status from Draft to Active.
- When finished with this exercise, Deactivate or Delete the Mix Design value you activated.
|