Form Type | Setting Name | Description |
---|
Activity | Allow WBS |
|
Batch Data Entry | - Configures the grid columns presented when doing batch data entry for multiple (like) forms
|
Capture Costs | - Turns on the ability to capture field costs that are associated with the form record
- Form specific costs can be added in the form settings after enabling "Capture Costs".
|
Density Test - Soil Nuclear Gauge | - Automatically creates / applies a number of system fields necessary to do a SNG density test using an Activity form
|
QC Search Results | - Configures the form-specific columns to display when filtering a QC grid to a specific form
|
Unit System | - Assigns a unit of measure (Imperial / Metric) to a form and is used to return the applicable specification values for that unit of measure
|
Sample
| Sample Material | - Associates a sample form to a material
|
Specimen Sizes | - Allows for control over which specimen sizes can be used with a sample form
- One or more specimen sizes can be associated with the form
- All specimen sizes available if this setting is not used
|
Capture Costs | - Turns on the ability to capture field costs that are associated with the form record
- Form specific costs can be added in the form settings after enabling "Capture Costs".
|
One Specimen Sample | - Forces the sample to only have one specimen associated with it
|
Turn Off Specimen Retrieval | - Turns off the question regarding scheduling (in the Scheduling system) a future specimen retrieval
|
Test | Test Material | - Associates the test form to one or many materials
|
Material Specification | - Associates the test form to one or many material specifications
|
Billing | - Default billing code for the test
|
Billing Quantity | - Default billing quantity for the test
|
Capture Costs | - Turns on the ability to capture lab costs that are associated with the test form record
- Form specific costs can be added in the form settings after enabling "Capture Costs".
|
Cost | - Default (billed) test cost for executing the test
|
Remove Specification Limit Operators From Reports | - Removes the specification range limit operators when displayed on a report (i.e. 65 - 90 will display instead of >=65 - <90)
|
Standard | - Default standard the test adheres to (i.e. ASTM standard number)
|
Test Default Specimen Size | - Default specimen size for the test that will be assigned in the test assignment process
|
Test Duration | - Default duration (days) it takes to execute the test
|