Purpose
The form setting: Density Test - (Soil Nuclear Gauge, Bituminous Nuclear Gauge) can only be applied to Activity forms. Before applying, the user must select the Unit of Measure. Prior to adding this form setting (Soil Nuclear Gauge, Bituminous Nuclear Gauge), the form will already have the following fields: Activity Number, Date, and Technician. When adding a Density Test form setting, the setting will create multiple fields, which will be discussed later in this article. The creation of this form is to mimic MetaField’s created Density Test forms, but allow for the user to modify/edit their own forms for Density tests.
Currently there are two Density Test form settings - Bituminous Nuclear Gauge and Soil Nuclear Gauge. MetaField is looking to add more in the near future: Sand Cone, Moisture Content, Drive Cylinder and One-Point.
Fields for Density Test - Soil Nuclear Gauge
Label | System Name | Field Type | ||
---|---|---|---|---|
Retest Of | RetestOf | Number | ||
Location | Location | Pick List with the Data Source: Density Locations | ||
Specifications | DensitySpecificiations | Section
| ||
Density Test | DensityTest | Section
|
Density Test - Soil Nuclear Gauge Specifications Section
Label | System Name | Field Type | ||
---|---|---|---|---|
Proctor | Proctor | Pick List with Data Source: Proctor
| ||
Soil Classification | SoilClassification | Text Box
| ||
No Moisture Specification | NoMoistureSpecification | Yes / No | ||
Lower Moisture Tolerance | LowerMoistureTolerance | Number | ||
Upper Moisture Tolerance | UpperMoistureTolerance | Number | ||
Require Maximum Specified Compaction | RequireMaximumSpecifiedCompaction | Yes / No | ||
Minimum Specified Compaction | MinimumSpecifiedCompaction | Number | ||
Maximum Specified Compaction | MaximumSpecifiedCompaction | Number | ||
Moisture Requires Retest | MoistureRequiresRetest | Yes / No |