Purpose

The form setting: Density Test - (Soil Nuclear Gauge, Bituminous Nuclear Gauge) can only be applied to Activity forms. Before applying, the user must select the Unit of Measure. Prior to adding this form setting (Soil Nuclear Gauge, Bituminous Nuclear Gauge), the form will already have the following fields: Activity Number, Date, and Technician. When adding a Density Test form setting, the setting will create multiple fields, which will be discussed later in this article. The creation of this form is to mimic MetaField’s created Density Test forms, but allow for the user to modify/edit their own forms for Density tests.

Currently there are two Density Test form settings - Bituminous Nuclear Gauge and Soil Nuclear Gauge. MetaField is looking to add more in the near future: Sand Cone, Moisture Content, Drive Cylinder and One-Point.

Fields for Density Test - Soil Nuclear Gauge

Label

System Name

Field Type

Retest Of

RetestOf

Number

Location

Location

Pick List with the Data Source: Density Locations

Specifications

DensitySpecificiations

Section

Info

Please see Density Test - Soil Nuclear Gauge Specifications Section below for included fields

Density Test

DensityTest

Section

Info

Please see Density Test - Soil Nuclear Gauge Density Test Section below for included fields

Density Test - Soil Nuclear Gauge Specifications Section

Label

System Name

Field Type

Proctor

Proctor

Pick List with Data Source: Proctor

Info

When the user is submitting data and they select a Proctor, the Proctor’s meta data (Such as: Soil Classification Code, Color, Size, etc.) will appear.

Depending on what the user selects, the below Soil Classification will pull in the Proctor meta data.

Soil Classification

SoilClassification

Text Box

Info

This is non-editable to the user submitting data. This data will be pulled based on what was selected as the Proctor

No Moisture Specification

NoMoistureSpecification

Yes / No

Lower Moisture Tolerance

LowerMoistureTolerance

Number

Upper Moisture Tolerance

UpperMoistureTolerance

Number

Require Maximum Specified Compaction

RequireMaximumSpecifiedCompaction

Yes / No

Minimum Specified Compaction

MinimumSpecifiedCompaction

Number

Maximum Specified Compaction

MaximumSpecifiedCompaction

Number

Moisture Requires Retest

MoistureRequiresRetest

Yes / No