Standard Count Method / Manual Count Method |
---|
Field | Description |
---|
Category | - Indicates the type / category of gauge (i.e. used for moisture and density or just density)
| Image RemovedImage Added |
Method | - Indicates which Method is being used to standardize / calibrate the gauge. (This selection dictates the majority of the remaining fields that will display)
Info |
---|
Manual Count methods assume you are maintaining standardization records outside of MetaField. MetaField allows you to create a Manual Count gauge so you can "standardize" one for density tests, but there are no business rules that compare standardization counts to previous counts to determine a pass / fail status of the gauge. |
|
Serial Number | - Serial Number for the gauge
|
Name | - Name of the gauge used for easy identification (i.e. "Blue Team Gauge", "Truck 1001 Gauge", etc.)
|
Make | - Make of the nuclear gauge
|
Model | - Model of the nuclear gauge
|
Rx Density Limit 1 (%)
| |
Rx Density Limit 2 (%) | - Not a required field. Available to support Troxler 3450 gauges.
|
Rx Moisture Limit (%)
| |
Calibration Date | - Date the nuclear gauge was last calibrated
|
Calibrated By | - Person who last calibrated the nuclear gauge
|
Require Density / Moisture Counts | - Set to TRUE / checked if you want to require field technicians to enter the gauge density and moisture counts for quality control / audit purposes.
|
Enter Moisture % on Test | - Set to TRUE / checked if you want to enter the Moisture % (versus the Weight of Water (PCF) value) value from the gauge display on SNG density tests.
|
Preferred Density Input | - Indicates the preferred value to input on a nuclear gauge density test - Wet / Dry Density
|
Office | - Office associated with the nuclear gauge
|
...
Prescale Factor | - Not a required field. Available for use if ASTM 2950D standards are required by the lab doing the testing.
|
Radioactive Decay Method |
---|
Field | Description |
---|
Category | - Indicates the type / category of gauge (i.e. used for moisture and density or just density)
| Image RemovedImage Added |
Method | - Indicates which Method is being used to standardize / calibrate the gauge. (This selection dictates the majority of the remaining fields that will display)
|
Serial Number | - Serial Number for the gauge
|
Name | - Name of the gauge used for easy identification (i.e. "Blue Team Gauge", "Truck 1001 Gauge", etc.)
|
Make | - Make of the nuclear gauge
|
Model | - Model of the nuclear gauge
|
Density Calibration Standard Count | - The density calibration standard count from the gauge
|
Density Isotope Half Life (Days) | - Density isotope half life (days) from the gauge
|
Moisture Calibration Standard Count | - The moisture calibration standard count from the gauge
|
Moisture Isotope Life (Days) | - Moisture isotope half life (days) from the gauge
|
Calibration Date | - Date the nuclear gauge was last calibrated
|
Calibrated By | - Person who last calibrated the nuclear gauge
|
Require Density / Moisture Counts | - Set to TRUE / checked if you want to require field technicians to enter the gauge density and moisture counts for quality control / audit purposes.
|
Enter Moisture % on Test | - Set to TRUE / checked if you want to enter the Moisture % (versus the Weight of Water (PCF) value) value from the gauge display on SNG density tests.
|
Office | - Office associated with the nuclear gauge
|
...
Gauge data can be extracted using the Extract Records buttons.
Image RemovedImage Added