Purpose

The following table outline the various lab test data inputs and controls for the various sample types.

Cylinders - Cast Cylinder, Grout Cylinder, Mortar Cylinder

FieldDescription
Sample
  • Sample number of the specimen to be tested
  • Read-only value
Set# - Spec#
  • Set number and Specimen number of the specimen to be tested
  • Read-only value
Project
  • Project number of the specimen to be tested
  • Read-only value
Specified Strength
  • Specified strength the specimen is suppose to reach
  • This value is entered in Field
  • Read-only value
Test Age
  • Test age of the specimen to be tested
  • Read-only value
Diameter 1 (in)
  • Enter the first measured diameter of the specimen
  • Unit of measure is inches
  • Allows up to two decimal places
Diameter 2 (in)
  • Enter the second measured diameter of the specimen
  • Unit of measure is inches
  • Allows up to two decimal places
Average Diameter (in)
  • System derived average of diameters entered
  • Read-only value
Height
  • Enter the length the specimen length
  • Unit of measure is inches
  • Allows up to two decimal places
L/D Ratio
  • System calculated length to diameter ratio
Correction Factor
  • If the specimen's length to diameter ratio is 1.75 or less you may enter a correction factor that is applied to the test results
  • Allows up to two decimal places
Load Strength (lbs)
  • Enter the load strength of the specimen - compression machine reading
  • Unit of measure is pounds
  • Only whole numbers are allowed
Compressive Strength (psi)
  • System calculated value of Compressive Strength
Capping Method
  • Record what type of capping method was used during testing
  • List of Capping Methods is controlled by your MetaField Business Administrator
Fracture Type
  • Enter the type of fracture observed during testing
  • List of Fracture Types is controlled by your MetaField Business Administrator
Remark Code
  • Enter the Remark Code that applies to the specimen tested
  • List of Remark Codes is controlled by your MetaFeld Business Administrator
Is Cut
  • If the specimen is cut during testing check this box
Tested Date
  • Record the date the specimen was tested
  • Defaults to the current date
Tested By
  • Enter the name of the person who performed the test
  • Defaults to the current logged in user
Untested
  • If a specimen is not tested (hold cylinders for example) select this box
  • When checked, you will not be required to complete many of the other fields on this screen
Notes
  • Optional area where a Lab user can record notes pertaining to the specimen
  • Once the specimen is set to Analyzed in Lab, these notes will display in Quality Control for project managers to see