The lab work queues are used to manage the progression of concrete / grout / mortar specimens through a general lab workflow through the use of various queues.

 

Work Queues

 

Work QueueDescription
To Receive
  • Specimens are logged and checked-in via the Field component, but have not yet been “Received” by the lab
ButtonFunction
Receive Specimens
  • Receives the marked specimens in to the lab workflow
Print Label
  • Prints a specimen label for marked specimens
  • Labs configured with a label printer (in Admin) will ask the user if they want to print a label when Receiving specimens
Print Receiving List
  • Prints a list of specimens in the To Receive queue
Change Lab
  • Changes the lab a specimen is associated with / checked into
View Field Data
  • Opens QC to view additional metadata (i.e. field test results) for a specimen
Testable
  • Specimens have been received by the lab, but have not yet reached their Test Age.
ButtonFunction
Modify Test Date
  • Changes the test date (and test age) for marked specimens
Print Early Break List
Print Early Density List 
  • Prints a break list / density list for a user-supplied test date
Print Label
  • Prints a specimen label for marked specimens
Change Lab
  • Changes the lab a specimen is associated with / checked into
View Field Data
  • Opens QC to view additional metadata (i.e. field test results) for a specimen
To Test
  • Specimens have been received by the lab and have reached their Test Age.
ButtonFunction
Modify Test Date 
Print Break List
Print Density List 
 
Enter Test Results 
View Break Remarks
View Lab Remarks 
 
Change Lab 
View Fracture Types 
View Field Data 



To Review
  • After lab results are entered and saved in the To Test Queue, the specimen will automatically move here.
  • For this queue, you can edit and approve test results entered.
  • To change test results, select the test and click Edit Results
  • For Cast Cylinders and Beam specimens, once approved the specimen will move to the Analyzed work queue and lab results are returned to Quality Control and Dashboard
  • For Density Test specimens, if testing is complete, the specimen will move to the Analyzed work queue and lab results are returned to Quality Control and Dashboard.
    However, if future testing must be performed on the Density Test specimen, it will move to the Testable work queue.


Analyzed
  • Specimen record will automatically move to the Analyzed queue after test data has been entered and approve
  • Once the Specimen is in the Analyzed queue, lab testing is considered finished.
  • Test results for Specimens in the Analyzed queue will now display in Quality Control for review and reporting by the project manager. 
  • Test results can be edited from this queue click Edit Results.
Tip
titleEnter / Edit Results Grid Navigation

When entering lab results data, the Tab key can be used to navigate right / left in the data grid. The up / down arrows can be used to navigate vertically in a column. 

 

...