Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents
Table of Contents

Setting Density Project Specifications

Info
titleBlank Project Specifications

If any field is left blank, the defaults (global settings) specified within MetaField Administration will be used.

Field Instructions

Soil Density Test Specifications

  • Any information added to this box will display to Field users for all Density Tests
Soil Density Test Specifications

Soil Density Test Specifications

  • You can enter specific moisture and soil classification specifications on a project level or for a specific soil classification and/or loction
  • Specifications entered here will be applied to Field as follows:
    1. System will look for a match on Location and Soil Classification
    2. System will look for a match on Location
    3. System will look for a match on Soil Classification
    4. System will look for a global project setting (no Location or Soil Classification)
    5. System will look at Admin settings
  • These fields only apply to Soil Nuclear Gauge, Sand Cone or Moisture Content Tests
  • Field users can override these default values in Field
  • The table will load in the order that the system will look up a match from Field.  
Field
Description

Location

  • Select one or many Locations to which these specifications should apply
  • If no Location is selected, system will assume all Locations not specified elsewhere in Project Specifications

Soil Classification

  • Select the classification to which this thse specifications should apply
  • If no Soil Classification is identified, system will assume all Soil Classifications not specified elsewhere

Moisture Specification

  • If box is left unchecked (Displays as YES in the table), Lower and Upper % Moisture Tolerance is entered in Field
  • If box is checked (Displays as NO in the table), Lower and Upper % Moisture Tolerance fields are hidden and all moisture results will be passing

Lower/Upper Moisture % Tolerance

  • Enter the lower / upper moisture tolerance values

Require Maximum Specified Compaction

  • Select this box if you would like Specified Maximum Compaction values entered
  • This box will default based on the current global setting in Administration

Minimum/Maximum Specified Compaction (%)

  • Enter the minimum / maximum specified compaction values
  • These values can be overridden in Field as necessary

Moisture Requires Retest

  • Select this box if you would like a Field user to perform a retest on Tests that fall outside the defined Moisture Tolerance.
  • If left unchecked, tests that fail on moisture will NOT be presented for a retest
  • Defaults to TRUE when adding a specification


Bituminous Density Test Specifications

Field
Description

Material

  • Identify the material to which the specifications apply
  • The list of materials is determined by your MetaField Business Administrator
  • This is a required field

Require Maximum Specified Compaction

  • Select this box if you would like Specified Maximum Compaction values entered
  • This box will default based on the current global setting in Administration

Minimum Specified Compaction (%)

  • Enter the minimum specified compaction for the material selected
  • Users can edit this value in Field
  • If left blank, global specifications will be provided in Field
  • If minimum specifications are provided, maximum specifications must also be entered

Maximum Specified Compaction (%)

  • Enter the maximum specified compaction for the material selected
  • Users can edit this value in Field
  • If left blank, global specifications will be provided in Field
  • If maximum specifications are provided, minimum specifications must be also entered

Required Retest

  • Select this box if you would like a Field user to perform a retest on Tests that fall outside the specified compaction range
  • If left unchecked, failing Bituminous Nuclear Gauge Tests will NOT be presented for retesting


Soil Density Project Specification Examples

Below are examples of how moisture and compaction settings will default in Field based on what is entered in Project Specifications and global settings in Admin.  

Info
iconfalse
titleExample Admin Settings
Minimum Specified CompactionMaximum Specified Compaction
90105
Lower Moisture ToleranceUpper Moisture Tolerance
-13
Soil Classification CodeLower Moisture ToleranceUpper Moisture ToleranceMoisture Failures Require Retest
SP -2No 
SC  -3No 
SP-SM  -1No 
Tip
iconfalse
titleExample 1 (Locations Only)

Project Specifications

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
Base Fill No  95100No
Base Fill: Sidewalk Yes-2393100No
Non-Structural Fill Yes  97100Yes

Field Defaults

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
Base FillSPNo (PS)  95 (PS)100 (PS)No (PS)
Base Fill: SidewalkSP-SMYes (PS)-2 (PS)3 (PS)93 (PS)100 (PS)No (PS)
Non-Structural FillSCYes (PS)-3 (Admin)3 (Admin)97 (PS)100 (PS)Yes (PS)
Tip
iconfalse
titleExample 2 (Soil Classifications Only)

Project Specifications 

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
 SPNo    No
 SP-SMYes-22  No
 CLYes  98100Yes

Field Defaults

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
Base FillSPNo (PS)  90 (Admin)105 (Admin)No (PS)
Base Fill: SidewalkSP-SMYes (PS)-2 (PS)2 (PS)90 (Admin)105 (Admin)No (PS)
Non-Structural FillCLYes (PS)-1 (Admin)3 (Admin)98 (PS)100 (PS)Yes (PS)
Tip
iconfalse
titleExample 3 (No Location / Soil Classification Defined)

Project Specifications

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
  Yes-2297100No

Field Defaults

LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
(Any)(Any)Yes (PS)-2 (PS)2 (PS)97 (PS)100 (PS)No (PS)
Tip
iconfalse
titleExample 4 (Location and Soil Classifications Defined)
LocationSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
Base FillSPYes-4192100Yes
Base Fill Yes  95100No

Sidewalk

 Yes  95102No
 SP-SMNo    No
Structural Fill Yes  98100No

Field Defaults

LocationSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
Base FillSPYes (PS)-4 (PS)1 (PS)92 (PS)100 (PS)Yes (PS)
Base FillSP-SMYes (PS)  95 (PS)100 (PS)No (PS)
SidewalkSCYes (PS) -3 (Admin)3 (Admin)95 (PS)102 (PS)Yes (PS)
Structural FillCLYes (PS)-1 (Admin)3 (Admin)98 (PS)100 (PS)No (PS)
Utility TrenchSP-SMNo (PS)  90 (Admin)105 (Admin)No (PS)