Setting Density Project Specifications

Info
titleBlank Project Specifications

If any field is left blank, the defaults (global settings) specified within MetaField Administration will be used.

Field Instructions

  • Any information added to this box will display to Field users for all Density Tests
  • Percent Compaction Decimal Precision

    • The decimal precision of the % Compaction calculation for both soil and bituminous tests can be controlled here for the project (if different than the global specification)
    • Options = Whole Number of Tenth (Whole Number is the default)

    Soil Density Test Specifications

    • You can enter specific moisture and soil classification specifications on a project level or for a specific soil classification and/or loctionlocation
    • Specifications entered here will be applied to Field as follows in this order / priority:
      1. System will look for a match on Location and Soil Classification
      2. System will look for a match on Location
      3. System will look for a match on Soil Classification
      4. System will look for a global project setting (no Location or Soil Classification)System will look at Admin at Admin (global) settings
    • These fields only apply to Soil Nuclear Gauge, Sand Cone or Moisture Content Tests
    • Field users can override these default values in Field if they have the appropriate permission level
    • The table will load in the order that the system will look up a match from Field.  
    Field
    Description

    Location

    • Select one or many Locations to which these specifications should apply
    • If no Location is selected, system will assume all Locations not specified elsewhere in Project Specifications

    Soil Classification

    • Select the classification to which this thse specifications should apply
    • If no Soil Classification is identified, system will assume all Soil Classifications not specified elsewhere


    Tip

    When adding specifications, multiple soil classifications can be selected at one time to assist with speed of data entry.


    Moisture Specification

    • If box is left unchecked (Displays as YES in the table), Lower and Upper % Moisture Tolerance is entered in Field
    • If box is checked (Displays as NO in the table), Lower and Upper % Moisture Tolerance fields are hidden and all moisture results will be passing

    Lower/Upper Moisture % Tolerance

    • Enter the lower / upper moisture tolerance values

    Require Maximum Specified Compaction

    • Select this box if you would like Specified Maximum Compaction values entered
    • This box will default based on the current global setting in Administration

    Minimum/Maximum Specified Compaction (%)

    • Enter the minimum / maximum specified compaction values
    • These values can be overridden in Field as necessary

    Moisture Requires Retest

    • Select this box if you would like a Field user to perform a retest on Tests that fall outside the defined Moisture Tolerance.
    • If left unchecked, tests that fail on moisture will NOT be presented for a retest
    • Defaults to TRUE when adding a specification


    Tip
    • The Delete Soil Specifications button above the grid can be used to delete multiple specification rows at one time
    • The Location filter control above the grid allows you to filter the specification grid to a specific location
    • The Soil Classification filter control above the grid allows you to filter the specification grid to a specific soil classification


    Bituminous Density Test Specifications

    Field
    Description

    Material

    • Identify the material to which the specifications apply
    • The list of materials is determined by your MetaField Business Administrator
    • This is a required field

    Require Maximum Specified Compaction

    • Select this box if you would like Specified Maximum Compaction values entered
    • This box will default based on the current global setting in Administration

    Minimum Specified Compaction (%)

    • Enter the minimum specified compaction for the material selected
    • Users can edit this value in Field
    • If left blank, global specifications will be provided in Field
    • If minimum specifications are provided, maximum specifications must also be entered

    Maximum Specified Compaction (%)

    • Enter the maximum specified compaction for the material selected
    • Users can edit this value in Field
    • If left blank, global specifications will be provided in Field
    • If maximum specifications are provided, minimum specifications must be also entered

    Required Retest

    • Select this box if you would like a Field user to perform a retest on Tests that fall outside the specified compaction range
    • If left unchecked, failing Bituminous Nuclear Gauge Tests will NOT be presented for retesting


    Soil Density Project Specification Examples

    Below are examples of how moisture and compaction settings will default in Field based on what is entered in Project Specifications and global settings in Admin.  


    Info
    iconfalse
    titleExample Admin Settings


    Minimum Specified CompactionMaximum Specified Compaction
    90105


    Lower Moisture ToleranceUpper Moisture Tolerance
    -13


    Soil Classification CodeLower Moisture ToleranceUpper Moisture ToleranceMoisture Failures Require Retest
    SP -2No 
    SC  -3No 
    SP-SM  -1No 




    Tip
    iconfalse
    titleExample 1 (Locations Only)

    Project Specifications

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    Base Fill
     

    No
     
     


    95100No
    Base Fill: Sidewalk
     

    Yes-2393100No
    Non-Structural Fill
     

    Yes
     
     


    97100Yes

    Field Defaults

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    Base FillSPNo (PS)
      


    95 (PS)100 (PS)No (PS)
    Base Fill: SidewalkSP-SMYes (PS)-2 (PS)3 (PS)93 (PS)100 (PS)No (PS)
    Non-Structural FillSCYes (PS)-3 (Admin)3 (Admin)97 (PS)100 (PS)Yes (PS)



    Tip
    iconfalse
    titleExample 2 (Soil Classifications Only)

    Project Specifications 

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
     

    SPNo
        




    No
     

    SP-SMYes-22
      


    No
     

    CLYes
      


    98100Yes

    Field Defaults

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    Base FillSPNo (PS)
     
     


    90 (Admin)105 (Admin)No (PS)
    Base Fill: SidewalkSP-SMYes (PS)-2 (PS)2 (PS)90 (Admin)105 (Admin)No (PS)
    Non-Structural FillCLYes (PS)-1 (Admin)3 (Admin)98 (PS)100 (PS)Yes (PS)



    Tip
    iconfalse
    titleExample 3 (No Location / Soil Classification Defined)

    Project Specifications

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
      


    Yes-2297100No

    Field Defaults

    LocationsSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    (Any)(Any)Yes (PS)-2 (PS)2 (PS)97 (PS)100 (PS)No (PS)



     
    Tip
    iconfalse
    titleExample 4 (Location and Soil Classifications Defined)


    LocationSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    Base FillSPYes-4192100Yes
    Base Fill
     

    Yes
     


    95100No

    Sidewalk

     


    Yes
      


    95102No
     

    SP-SMNo
        




    No
    Structural Fill
     

    Yes
      


    98100No

    Field Defaults

    LocationSoil ClassificationHas Moisture SpecificationLower Moisture ToleranceUpper Moisture ToleranceMinimum Specified CompactionMaximum Specified CompactionMoisture Failures Require Retest
    Base FillSPYes (PS)-4 (PS)1 (PS)92 (PS)100 (PS)Yes (PS)
    Base FillSP-SMYes (PS)
     
     


    95 (PS)100 (PS)No (PS)
    SidewalkSCYes (PS) -3 (Admin)3 (Admin)95 (PS)102 (PS)Yes (PS)
    Structural FillCLYes (PS)-1 (Admin)3 (Admin)98 (PS)100 (PS)No (PS)
    Utility TrenchSP-SMNo (PS)
      


    90 (Admin)105 (Admin)No (PS)