The lab work queues are used to manage the progression of concrete / grout / mortar specimens through a general lab workflow through the use of various queues.

 

Work Queues

Work QueueDescription
To Receive
  • Specimens are logged and checked-in via the Field component, but have not yet been “Received” by the lab
ButtonFunction
Receive Specimens
  • Receives the marked specimens in to the lab workflow
Print Label
  • Prints a specimen label for marked specimens
  • Labs configured with a label printer (in Admin) will ask the user if they want to print a label when Receiving specimens
Print Receiving List
  • Prints a list of specimens in the To Receive queue
Change Lab
  • Changes the lab a specimen is associated with / checked into
View Field Data
  • Opens QC to view additional metadata (i.e. field test results) for a specimen
Testable
  • Specimens have been received by the lab, but have not yet reached their Test Age.
ButtonFunction
Modify Test Date
  • Changes the test date (and test age) for marked specimens
Print Early Break List
Print Early Density List 
  • Prints a break list / density list for a user-supplied test date
Print Label
  • Prints a specimen label for marked specimens
Change Lab
  • Changes the lab a specimen is associated with / checked into
View Field Data
  • Opens QC to view additional metadata (i.e. field test results) for a specimen
To Test
  • Specimens have been received by the lab and have reached their Test Age.
ButtonFunction
Modify Test Date 
Print Break List
Print Density List 
 
Enter Test Results 
View Break Remarks
View Lab Remarks 
 
Change Lab 
View Fracture Types 
View Field Data 



To Review
  • After lab results are entered and saved in the To Test Queue, the specimen will automatically move here.
  • For this queue, you can edit and approve test results entered.
  • To change test results, select the test and click Edit Results
  • For Cast Cylinders and Beam specimens, once approved the specimen will move to the Analyzed work queue and lab results are returned to Quality Control and Dashboard
  • For Density Test specimens, if testing is complete, the specimen will move to the Analyzed work queue and lab results are returned to Quality Control and Dashboard.
    However, if future testing must be performed on the Density Test specimen, it will move to the Testable work queue.


Analyzed
  • Specimen record will automatically move to the Analyzed queue after test data has been entered and approve
  • Once the Specimen is in the Analyzed queue, lab testing is considered finished.
  • Test results for Specimens in the Analyzed queue will now display in Quality Control for review and reporting by the project manager. 
  • Test results can be edited from this queue click Edit Results.

Enter / Edit Results Grid Navigation

When entering lab results data, the Tab key can be used to navigate right / left in the data grid. The up / down arrows can be used to navigate vertically in a column. 

 

Lab Filters


Across the top of Lab Work Queues are several filter choices that allow you to refine the data returned within each Work Queue.

FieldDescription

Lab

  • Select from a dropdown list your desired lab
  • Default is All Labs

Start/End Test Date

  • Enter a date or select a date from the calendar
  • Specimens will be returned that have a corresponding test date

Project Number

  • Type in a complete or partial project number

Sample Number

  • Type in a specific sample number
  • Results returned will match the number entered exactly

Set Number

  • Type in a specific set number
  • Results returned will match the number entered exactly

Specimen Number

  • Type in a specific specimen number
  • Results returned will match the number entered exactly



 

Difference in Test Age / Test Date in Lab and Quality Control

After a specimen is checked into Lab, the specimen Test Date / Test Age can be updated in Lab.  You will not see this updated Test Date / Test Age in MetaField Quality Control until after a specimen status is updated to Analyzed in Lab.   

Analyzed Lab Status

Analyzed marks the last status of a specimen in Lab. However, in MetaField a specimen status can be changed from Analyzed to Review or Complete. This change of status in MetaField is not reflected in Lab.

 

 