Sample Section

After you have selected a project Sample Type (Add Sample button) you will be taken to the main Sample screen.

FieldDescription
Sample Type
  • Visual reference to the sample type selected
Technician
  • Select the person who is performing the work
  • Defaults to the current user
  • This is a required field
Date Logged / Cast
  • Record the date by typing in a value or selecting from the calendar
  • This is a required field
Placement Location
  • Select corresponding location from the drop-down
  • List is controlled by your MetaField Business Administrator
  • This is a required field
Location Details
  • Type in additional location information
  • 500 character limit.
  • This is a required field
Longitude
  • Longitude (in degrees) where the activity is happening

Up to 8 decimal places are allowed in the longitude value.

Latitude
  • Latitude (in degrees) where the activity is happening

Up to 8 decimal places are allowed in the latitude value.

Project Location ID
  • Client defined field to identify granular site locations based on business process.
  • This information displays in QC only, not on reports.
Alternate Sample / Set #
  • Used to store an alternate / cross-reference sample and set number
  • Optional and not used very often

Specifications Section

Click the Specifications button at the bottom of the Sample screen to open the Specifications section.

FieldDescription

Specified Strength

Modulus of Rupture

  • Enter the Specified Strength for the sample
  • Defaults if defined in Project Specifications
  • Modulus of Rupture only applies to Beam sample types
Specified Strength Test Age
  • Enter the test age for the Specified Strength (i.e. 28 days)
  • Defaults if defined in Project Specifications
Min/Max Wet Unit Weight
Min/Max Dry Unit Weight 
  • Enter unit weight specifications
  • Displays for Density Test sample types
  • Defaults if defined in Project Specifications
Lower / Upper Specified Air Limit
  • Air Content low / high limit specifications
  • Defaults if defined in Project Specifications
Lower / Upper Specified Slump
  • Slump low / high limit specifications
  • Defaults if defined in Project Specifications
Lower / Upper Specified Spread
  • Spread low / high specifications
  • Defaults if defined in Project Specifications
Lower / Upper Flow Cone Limit
  • Flow Cone low / high specifications
  • Defaults if defined in Project Specifications
Lower / Upper Cone Penetration Limit
  • Cone Penetration low / high specifications
  • Defaults if defined in Project Specifications