Purpose
The LIMS work queues are used to manage the progression of concrete / grout / mortar specimens through a general lab workflow through the use of various queues.
Work Queues
Work Queue | Description |
---|
To Receive | - Specimens are logged and checked-in via the Field component, but have not yet been “Received” by the lab
Button | Function |
---|
Receive Specimens | - Receives the marked specimens in to the lab workflow
| Print Label | - Prints a specimen label for marked specimens
- Labs configured with a label printer (in Admin) will ask the user if they want to print a label when Receiving specimens
| Print Receiving List | - Prints a list of specimens in the To Receive queue
| Change Lab | - Changes the lab a specimen is associated with / checked into
| Add Specimen | - Adds a missing specimen to a selected set
| View Field Data | - Opens QC to view additional metadata (i.e. field test results) for a specimen
- "i" icon in the grid on the far right
|
|
Testable | - Specimens have been received by the lab, but have not yet reached their Test Age.
Button | Function |
---|
Modify Test Date | - Changes the test date (and test age) for marked specimens
| Print Early Break List Print Early Density List | - Prints a break list / density list for a user-supplied test date
- Gives user the option to print for current sample type or all sample types
- Sorts report to match sort order applied to the grid
| Print Label | - Prints a specimen label for marked specimens
| Change Lab | - Changes the lab a specimen is associated with / checked into
| Add Specimen | - Adds a missing specimen to a selected set
| View Field Data | - Opens QC to view additional metadata (i.e. field test results) for a specimen
- "i" icon in the grid on the far right
|
|
To Test | - Specimens have been received by the lab and have reached their Test Age
Button | Function |
---|
Modify Test Date | - Changes the test date (and test age) for marked specimens
| Print Break List Print Density List | - Prints a break list / density list for a user-supplied test date
- Gives user the option to print for current sample type or all sample types
- Sorts report to match sort order applied to the grid
| Enter Test Results | - Opens data entry grid to enter test results
| View Break Remarks View Lab Remarks | - Displays a legend of break remarks / lab remarks that can be assigned to tested specimens
| Change Lab | - Changes the lab a specimen is associated with / checked into
| View Fracture Types | - Displays a legend of fracture types that can be assigned to tested specimens
| Add Specimen | - Adds a missing specimen to a selected set
| View Field Data | - Opens QC to view additional metadata (i.e. field test results) for a specimen
- "i" icon in the grid on the far right
|
|
To Review | - After lab results are entered and saved in the To Test Queue, the specimen will automatically move here for lab manager review /auditing
Button | Function |
---|
Edit Results | - Allows for lab results / data input to be modified
| Approve | - Designates tested specimen results as "Approved" and ready for project manager review in QC
- Status changed to Analyzed in the QC module and moved to the Done queue in Lab
| Add Specimen | - Adds a missing specimen to a selected set
| Revert Test Results | - Removes any lab data and puts the specimen back in the Testable or To Test queue
| View Field Data | - Opens QC to view additional metadata (i.e. field test results) for a specimen
- "i" icon in the grid on the far right
|
|
Done | - Specimen record will automatically move here after it is approved in the To Review queue
Button | Function |
---|
Edit Results | - Allows for lab results / data input to be modified
| Add Specimen | - Adds a missing specimen to a selected set
| Revert Test Results | - Removes any lab data and puts the specimen back in the Testable or To Test queue
| View Field Data | - Opens QC to view additional metadata (i.e. field test results) for a specimen
- "i" icon in the grid on the far right
|
|
Lab Filters