Table of Contents |
---|
About QC - Density Testing
This section of QC allows you to review Density Tests as well as build and finalize reports.
When you first start using QC you will need to search for a project from the project search panel. Recent projects you have worked with will display below for easy access.
Select View Tests to open the project and see the associated Tests.
Click on image to enlarge.
View Tests
Only projects with Density Tests will have a View Tests link.
Using Density Testing Filters
To limit the test results displayed, you may set various filters in the filter pane and select Filter. These filter settings will be retained until you select Clear All or Logout.
Click on image to enlarge.
Edit Density Test Results
To edit a Density Test, select the pencil icon next to the test. This will open the test for editing. Depending on your permissions you will be able to edit various fields.
Reviewing All Density Test Fields
Not all fields are available for viewing from the Test Review table. Opening the test for editing will allow you to review all test data.
Click on image to enlarge.
Field Notes
If a technician has added Field Notes to a Test, an icon will display on the Test Review table.
Click on image to enlarge.
NEW IMAGE NEEDED FOR OVEN BURN
To view the note, open the test for editing and scroll to the bottom.
Click on image to enlarge.
Report Comments
You can add comments to a single density test. These comments will display on the client report.
To add Report Comments, open the test for editing and scroll to the bottom.
Click on image to enlarge.
Changing Test Status
To update a test status, check the box next to one or more tests and select Set Status.
Click image to enlarge.
NEW IMAGE NEEDED FOR OVEN BURN
Changing Status of Multiple Tests
Select the top checkbox to select all tests in the current view at one time.
Test Status Definitions
Complete Status and Reports
Only Tests in the status of Complete may be added to a report.
Status | Definition |
---|---|
Analyzed |
|
Pending |
|
Complete |
|
Review |
|
Examples of Using the Review Status
Review can be used if the test review has been started, but may take more time to complete.
The project manager can assign the status as a reminder that he is waiting for information about this test.
Creating a Soil Density Report
Reports - Test Status = Complete
Only tests with the status of Complete may be added to a Sand Cone, Soil Nuclear Gauge or Bituminous Nuclear Gauge Report.
Step | Description | Example | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1. | Go to Quality Control and select Density Testing. | Click image to enlarge. | ||||||||||
2. | Select the desired project. If you have previously been working in MetaField, the last project selected will display. To view another project, click Change Project. |
| ||||||||||
3. | Verify that the test status of those you want to include on your report are set to Complete. | |||||||||||
4. | Check the box next to desired tests. Expand table Use the bottom table controls to expose more tests on the page. You can only add tests from a single page. Click image to enlarge. | Click image to enlarge. | ||||||||||
5. | (Optional) You can view your report by clicking Preview Report. | Click image to enlarge. | ||||||||||
6. | There are two options when adding tests to a report: 6.A. Select Draft Report button. This will create a report and send this report to the Draft Review portion of Quality Control. 6.B. Select Finalize Report button. This will create a report and send this report to Delivery. | Click image to enlarge. | ||||||||||
7. | Depending on which button is selected and how your Business Administrator has configured your reports, you may see some of the options below.
| Click image to enlarge. |
View Legend
Click to enlarge image.
NEW IMAGE NEEDED FOR OVEN BURN